Single Zone Tape

Single Zone Tape

The Andel Floodline Single Zone Tape is designed for high sensitivity areas.  The sensor can be wetted and dried multiple times.  The polyester woven construction with no exposed conductors allows the sensor to have a very high strength and abrasion resistance.  The sensor can be supplied in any length either pre-connected in the factory or for cutting on site.

Multi-4 4 Zone Detection Cable

Multi-4 4 Zone Detection Cable

The Andel Floodline Multi-4 4 Zone Detection Cable is designed in conjunction with the 4 zone junction boxes to allow up to 4 zones to individually report on a single leader cable.  The sensor has an inner pvc core with cellulosic covered detection cores.  All covered by a multi-filament cellulosic outer covering.  This sensor incorporates a special colour change system giving permanent evidence that the cable has been wet and where, even after it has dried.

Multi-8 8 Zone Detection Cable

Multi-8 8 Zone Detection Cable

The Andel Floodline Multi-8 8 Zone Detection Cable is designed in conjunction with the 8 zone junction boxes to allow up to 8 zones to individually report on a single leader cable.  The sensor has a tough polymetric, low smoke and fume, zero halogen construction.  This cable is also available with pre-terminated connectors to make the system fully plug and play using special junction boxes which automatically tell the system to start or end each zone.

Plug & Play Autoconnect System

Plug & Play Autoconnect System

The Andel Floodline Plug & Play Autoconnect System is designed to provide instant, foolproof connection for a quick, no-hassle installation.  Connections are made by using a special version of the industry standard RJ45 type network connector.  This system is only available using the Multi-8 8 Zone Detection Cable.  Both Multi-8 8 Zone Detection Cable and Patch-Leader Cable are available in a range of standard pre-terminated lengths 5m, 7.5m, 10m and 15m.  The system is comprised of in/out couplers.  The SOL coupler is the start of line junction box which connects the leader cable to the sensor cable.  The autocoupler connects one detection cable to another using in-built system logic to end one detection zone and launch another detection zone giving each zone its relative position and zone address.  The EOL coupler is the end of line junction box which terminates the last detection zone in the line.

Point Sensor

Point Sensor

The Andel Floodline Point Sensor is designed for areas where sensing cable cannot be used like harsh environments such as plant room etc.  Made with a high density plastic body with stainless steel/nickel plated brass probes covered with a heavy duty stainless steel guard plate.  The sensor is capable of being mounted horizontally or vertically.  Encapsulation option for immersion proofing is available.

Oil Sensor

Oil Sensor

The Andel Floodline Oil Sensor is designed using an optical sensor which can be wiped clean after coming in contact with any conductive liquid.  The sensor has a high density plastic body sealed against immersion and covered with a heavy duty stainless steel guard plate.  The sensor can be mounted either vertically or horizontally.

Tundish/Overflow Sensor

Tundish/Overflow Sensor

The Andel Floodline Tundish/Overflow Sensor is designed to be attached to the toilet cistern or other tank.  The sensor can be wetted and dried multiple times.  The sensor is made of a tough plastic bowl and connection box with stainless steel sensor probes.  Can be fixed to a standard 22mm overflow pipe exiting the cistern/tank. 

Pipe-in-Pipe Sensor (Double Containment)

Pipe-in-Pipe Sensor (Double Containment)

The Andel Floodline Pipe-in-Pipe Sensor is designed for detecting liquids within double containment piping systems.  There are two versions available, one using probes for water and one using an optical sensor for oil and other conductive liquids.  Made with high density plastic body, fully encapsulated against immersion.  Stainless steel probes and a resistant plastic tip for the oil pipe-in-pipe sensor.  Once activated these sensor can be cleaned and re-used multiple times.  Built with a 1/2" BSP fitting as standard, but other sizes are available on request

Flexi-Pad Sensor

Flexi-Pad Sensor

The Flexi-Pad Sensors have been specifically designed for laying in narrow voids (too small for point sensors) or wrapped around pipes at valves or joints where leaks are more likely to occur. The Flexi-Pad Sensor can be used singly, or in groups with a number of sensors being connected together to form one zone.  A removable fabric cover assists absorption and protects the sensing surfaces. Flexi-Pad Sensors can be wetted and dried any number of times provided the sensor element/fabric cover is not contaminated with a substance that irrevocably changes its electrical characteristics. Examples may be vending machine syrup, chemical floor treatments, paints etc.  After wetting, the cover can be replaced with a spare or removed for drying.

FGS1000 Refrigerant Gas Detector

FGS1000 Refrigerant Gas Detector

The Floodline FGS1000 Refrigerant Gas Sensor can provide either a stand-alone Refrigerant Alarm system OR be included as part of a larger water/oil leak detection system or can be used to provide a dedicated refrigerant gas detection alarm package.  The Floodline FGS100 complies to BS EN378 and detects Refrigerant Gases to HSE Occupational Exposure Limits, the sensitivity controls are calibrated with 1000ppm gas to air mixture using the specified gas (R410A / R407C / R134a etc).  The operating scope of BS EN378 specifies the installation of fixed refrigerant leak detectors in both existing and new system of all sizes with certain exceptions for small unit and self-contained systems.  The Floodline FGS1000 sensors are connected to a standard Floodline Control Panel giving audible and visual alarm features in addition to the facility for onward communication to BMS etc.