| Single  & Two Zone Oil Detection Units 
 The FLD  range has been designed to monitor critical areas for oil leaks and spillages  via spot optical sensors. Up to 10 sensors can be connected to each zone.   The unit includes an audible warning device, mute push button, flashing  8mm red alarm lamps and 8mm Control live green lamp.  Once an oil leak has  been detected, the controllers red “Alarm” lamp will start to flash, the  audible warning device will start and the common alarm relay will close. The  unit will remain in this condition even if the oil is removed from the sensor.  Only muting the alarm will stop the sounder, turn on the lamp permanently and  de-latch the alarm. If oil is removed from the sensor before pressing the “Mute  Alarm” button, after Muting the alarm lamp will extinguish indicating that oil  is no longer present and the common alarm relay de-energise. However if oil is  still being detected only the audible warning will stop leaving the lamp  permanently on and the relay energised. Only when the oil has been removed will  the lamp extinguish and the relay de-energise. AllFLD units have a common alarm set of volt free contacts for  onward signalling to Building Management Systems, telephone dialler, control  systems and shut off valves. Features  
                      Large indication LED lamps for ease of Alarm  identification from a distanceOn board audible warning device to alert local  operators of a problemAlarms latched until Mute operated to give  indication of transient water leaksCommon alarm relay to onward signal to a BMS or  used to shutdown Oil valvesLamps, relay and Horn test Facility to ensure that  the unit is working correctlySmall foot print, wall or surface mounted 2 Zone Oil Detection System With Battery Backup  
 This unit contains a battery to allow the unit to  operate during a power cut. The life of the battery is dependent upon the  number of sensors that are connected but would be in the range of 5 and 10  hours. The size of the housing is size 200mm x 150mm x 80mm deep, Surface  mounted, cable entry/exit via glands on any side or through the back. Input  power to the unit 230VAC, but any AC voltage can be catered for. Sensing  voltage is 5 Volts DC. Large indication LED lamps for ease of Alarm  identification from a distance. On board audible warning device to alert local  operators of a problem. Common alarm relay to onward signal or used to shutdown  valves. Lamps, relay and Horn test Facility to ensure that the unit is working  correctly. Small foot print, wall or surface mounted.  Four Zone  Oil Detection Unit With Events History  
 The FLD4  has been designed to monitor four independent zones in critical areas for oil  leaks via optical sensors. Up to 10 sensors can be connected to each zone. The  unit contains an audible warning device, Mute push button, History &  history Exit buttons and a back lit alphanumeric display. A non-volatile event  history is included as standard to show the past 250 events. This can be used  to identify sensitive areas or faulty equipment. When oil is detected by one of  the zones, the display will start to flash with the location, the audible  warning device will start and the zone alarm relay closes. The unit will remain  in this condition even if the oil is removed from the sensor. Muting the alarm  will stop the sounder and the display flashing. If oil is removed from the  sensor before pressing the “Mute Alarm” button, after Muting the display will  revert back to its normal state indicating that oil is no longer present and  the zone alarm relay will de-energise. However, if oil is still being detected  only the audible warning will stop leaving the location in the display and the  zone alarm relay energised. Only when the oil is removed from the sensor will  the display revert back to its normal mode.  The FLD4 as standard has an individual  relay for each zone with a normally closed set of volt free contacts. All four  relays can be used to individually onward signal to a Building Management  Systems, telephone dialler, control systems and oil Shut Off valves or can be  wired together to give a common alarm output.  Features  
                      Alphanumeric display for ease of Alarm  identification from a distanceOn board audible warning device to alert local  operators of a problemAlarms latched until Mute operated to give  indication of transient oil leaksLamps, relay and Horn test Facility to ensure that  the unit is working correctlySmall size foot print, wall or surface mountedIndividual Zone sensitivity adjustment allowing any  zone to be set for high to low sensitivity250 Past Event History |